Другие характеристики:
APPLICATION
Cables for telephone and radio communication, paired are designed for operation at voltage up to 380V frequency up to 10 kHz at subscriber telephone and radio lines.
Trade mark Name of cable Laying method
ПРППМ Cables for telephone and radio communication, paired with copper conductor, with PE insulation and sheath Direct burial, duct-work, external wall,
ПРПВМ Cables for telephone and radio communication, paired with copper conductor, with PE insulation and PVC sheath Direct burial, duct-work, external wall
CONDUCTOR – soft copper wire with nominal diameter 0,8, 0,9 mm and 1,2 mm.
INSULATION - polyethylene.
SHEATH - sheath from light stabilized polyethylene for a cable ПРППМ and lightheat-resistant plastic compound for a cable ПРПВМ covers two parallel insulated conductors.
TECHNICAL DATA
DC conductor resistance for 1 km of cable at the temperature +20˚С for conductor diameter:
0,8 mm - 36,0 Ohm;
0,9 mm - 28,4 Ohm;
1,2 mm - 16,0 Ohm.
Electric resistance of insulation between the wires for 1 km of cable at the temperature +20˚С is not less than 10000 МОhм.
Operational temperature for a cable ПРППМ is from -60˚С up to +50˚С; for a cable ПРПВМ - from-40˚С up to +60˚С.
Cables resist to air humidity up to 98 % at the temperature up to +35˚С.
Permissible temperature for installation of cables should not be below-10˚С and bending radius not less than 10 times the thickness of the cable.
Cables are designed for laying at soil, duct-works, external walls.
The delivery length is not less than 500 meters, 250m and more cable pieces are possible to deliver but not more than 15% of total length of batch.
Service life of cables is not less than 10 years.