More than half a century
in the market!
Product catalog

Automotive and railway vehicle wires

ППСВВМнг(А), ППСТВМнг(А), КПСВВМнг(А), КПСТВМнг(А), ППСВВМнг(А)-LS
TS BY 500017371.081-2016

DESIGNATION

Railway vehicle wires and cablesare designed for internal and external connections of railway vehicles' electrical equipment including special railway vehicles: group hardwiring and connection of electrical equipment located on railway vehicles' moving parts, intercar and intersection joints with rated alternating current voltage frequency up to 400 Hz: for 660 V cables (1000 V for direct current), for 660, 1000, 2000, 3000, 4000 V (1000, 1500, 3000, 4500, 6000 V for direct current).

Wire models and their definitions shall correspond to the details given in the table below:

Model

Definition

ППСВВМнг(А)

Wire with PVC insulation in PVC sheath, fire-resistant, for railway vehicles

ППСВВМнг(А)-LS

 

Wire with fire-safe insulation and sheath and low smoke and gas emission for railway vehicles

ППСТВМнг(А)

Wire with TEP insulation in PVC sheath, fire-resistant, for railway vehicles

КПСВВМнг(А)

Cable with PVC insulation in PVC sheath, fire-resistant, for railway vehicles

КПСТВМнг(А)

Cable with TEP insulation in PVC sheath, fire-resistant, for railway vehicles

ARRANGEMENT

Rated conductor area range, numbers of conductors, rated voltage values for wires and cables shallcorrespond to the details given in the table below:

Model

Ratedvoltage, V

Numberofconductors

Rated conductor area range, mm2

Alternating current up to 400 Hz frequency

Directcurrent

ППСВВМнг(А)

ППСВВМнг(А)-LS

ППСТВМнг(А)

660

1000

1

from 0.5 to 300

1000

1500

2000

3000

3000

4500

4000

6000

КПСВВМнг(А)

КПСТВМнг(А)

660

1000

2-37

from 1.5to2.5

 

CONDUCTOR:copper, stranded.

INSULATION:

forППСВВМнг(А), КПСВВМнг(А) models - fire-resistant PVC compound;

forППСВВМнг(А)-LS model - fire-resistant PVC compoundwith low smoke and gas emission;

forКПСТВМнг(А), ППСТВМнг(А) models - thermoelastoplast (TEP);

SHEATH:Fire-resistant PVC compound; forППСВВМнг(А)-LS model - fire-safe PVC compoundwith low smoke and gas emission.

TECHNICALSPECIFICATIONS

Wires are resistant to diesel fuel, rain and ozone effect, abrasion, dust, hoarfrost, high humidity, folding, twisting and pressing.

Wires do not spread combustion when laid as harness.

Wires and cables shall be resistant to low ambient temperatures up to -60°C.

Wires and cables shall be resistant to high ambient temperatures not lower than +70°C.

Wires and cables shall be resistant to ambient temperature changes from +70°C to -60°C.

Wires and cables shall be resistant tocontinuous effect of relative atmospheric humidity up to 100% at ambient temperature up to +25°C.

Wires and cables shall be resistant to solar radiation.

Wires and cables shall be mounted at temperatures not lower than -15°С. Minimal operating bend radius shall not be less than five outer diameters of the wire or cable. The operating bend radius of wires and cables should be at least six outer diameters of the wire or cable.

Factory cable length - not less than 100 m. Supplies of wires and cables of not less than 20 m at a quantity of not more than 20% of total length are allowed.

Operational life - not less than 30 years.

Regulations: Technical SpecificationsBY 500017371.081-2016