Monitoring and control cables КВВГ, КВВГЭ, КВВГнг(А), КВВГЭнг(А), КВВГнг(А)-LS, КВВГЭнг(А)- LS

Control cables are designed for connectionof electrical devices and terminal blocks of electric switchgearswith rated alternating voltage up to 660 V and 100 Hz frequency or direct voltage up to 1000 V, for indoors hardwiring, channel and tunnelhardwiring in aggressive environmental conditionsin the absence of mechanical influence on the cable.

Armored control cable КВКбШв, КВКбШвнг(А), КВКбШвнг(А)-LS

Cable is designed for connection of electrical devices and terminal blocks of electric switchgearswith rated alternating voltage up to 660 V and 100 Hz frequency or direct voltage up to 1000 V.

Flat cables for elevators and lifts КВПЛ, КВПЛУ, КВПЛК, КВПЛЭ, КВПЛнг(А)-LS, КВПЛУнг(А)-LS

Flat cables for elevators and lifts are designed for cabling of passenger and general-purposefreightelevators with rated alternating voltage of 300/500 V and 60 Hz frequency and for interference-protected connection of sensors and devices connected with elevator equipment room.

Fire-resistant flame-retardantcontrol cableswith low gas and fume emission КВВГнг(А)-FRLS, КВВГЭнг(А)-FRLS

Cables are designed for connection of electrical deviceswith alternating voltage up to 660 V and 100 Hz frequency or direct voltage up to 1000 V.

Flexible control cables КГВВ, КГВВ-ХЛ, КГВВнг(А), КГВВнг(А)-ХЛ, КГВВнг(А)-LS, КГВЭВ, КГВЭВ-ХЛ, КГВЭВнг(А), КГВЭВнг(А)-LS, КГВЭВнг(А)-ХЛ, КГВВз, КГВВз-ХЛ, КГВВзнг(А), КГВВзнг(А)-ХЛ, КГВВз-П, КГВВз-П-ХЛ, КГВВ-П, КГВВ-П-ХЛ, КГВВнг(А)-П, КГВВнг(А)-П-ХЛ

Cables are designed for connection to electrical devices with alternating voltage up to 660 V and up to 100 Hz frequency or direct voltage up to 1000 V.

Control cable with copper conductors in halogen-free polymer compound insulation and sheath. КППГнг(А)- HF, КППГЭнг(А)- HF

Cables are designed for power transmission and distribution in fixed electrical facilities with rated alternating voltage of 0.66 kV and up to 100 Hz frequency, including application in nuclear power plants (NPP) out of containment areas.

Fire-resistant, flame-retardant control cable with halogen-free polymer compound insulation and sheath КППГнг(А)-FRHF

Fire-resistant, flame-retardant control cable with halogen-free polymer compound insulation and sheath are designed for power transmission and distribution in fixed electrical facilities with rated alternating voltage of 0.66 kV and up to 100 Hz frequency.

Control and data transfer cables КУПД В, КУПД ЭВ, КУПД ВЭ, КУПД ЭВЭ, КУПД ВК, КУПД ЭВК, КУПД ВЭК, КУПД ЭВЭК, КУПДнг(А) В, КУПДнг(А) ЭВ, КУПДнг(А) ВЭ, КУПДнг(А) ЭВЭ, КУПДнг(А) ВК, КУПДнг(А) ЭВК, КУПДнг(А) ВЭК, КУПДнг(А) ЭВЭК, КУПДнг(А)-LS В, КУПДнг(А)-LS ЭВ, КУПДнг(А)-LS ВЭ, КУПДнг(А)-LS ЭВЭ, КУПДнг(А)-LS ВК, КУПДнг(А)-LS ЭВК, КУПДнг(А)-LS ВЭК, КУПДнг(А)-LS ЭВЭК, КУПДнг(А)-FRLS В, КУПДнг(А)-FRLS ЭВ, КУПДнг(А)-FRLS ВЭ, КУПДнг(А)-FRLS ЭВЭ, КУПДнг(А)-FRLS ВК, КУПДнг(А)-FRLS ЭВК, КУПДнг(А)-FRLS ВЭК, КУПДнг(А)-FRLS ЭВЭК

Cables are designed for transmission of signals to control devices applied for operating mechanisms remote control and for inter-device connection with up to 600 V alternating voltage and 400 Hz frequency or 1000 V direct voltage. УХЛ1 and ХЛ1 climatic modifications under GOST 15150 for other cables. Temperature range for УХЛ1: from -40°С to +70°С; for ХЛ1: from -50°С to +70°С

Control cables with polyethylene insulation in polyvinylchloride compound sheath. КУПВ, КУПВ-П, КУПВ-Пм

Control cables are designed for transmission of low power control signals with alternating voltage up to 250 V and 1000 Hz frequency or direct voltage up to 350 V.

Fire-resistant cables for fire safety and fire alarm systems. Fire-resistant cables for fire safety and fire alarm systems.

Cables for fire safety and fire alarm systems (hereinafter – “cables”) are designed for single and group cabling for alternating voltage of up to 300 V and up to 10 kHz frequency or direct voltage of 420 V in fire-safety systems, fire and security alarm systems, fire detection systems, fire warning and evacuation control systems, emergency lighting on evacuation routes, emergency ventilation and smoke protection systems, automatic fire extinguishing systems and in other systems keeping operational during 180 minutes in fire conditions as well as in the areas of increased fire risk (subway, industrial facilities, schools, hospitals, office buildings, high-rise buildings).