More than half a century
in the market!

Product catalog

Flexible armored power cables

КГВКбГ, КГВКбШв

DESIGNATION

Power cables are designed for mobile machines, mechanisms and equipment connection to power lines or mobile power sources with alternating voltage up to 660 V and up to 400 Hz frequency or direct voltage up to 1000 V.

Cables of following models are manufactured:

Model

Definition

КГВКбГ

 

Multi-core flexible cable in PVC insulation, armored with galvanized steel round wires, with no outer covering

КГВКбШв

Multi-core flexible cable in PVC insulation, armored with galvanized steel round wires, with PVC compound protection hose

ARRANGEMENT

CONDUCTOR:copper, stranded.

INSULATION: PVC compound. Insulated conductors have distinctive color.

STRAND:insulated conductors of two- three- and four-core cables are stranded between each other. In five-core cables insulated conductors are stranded around PVC compoundkordel.

COREWRAPPING: PVCcompound.

ARMOR: galvanized steel round wires armor with a diameter of 0.3 mm. Armor coverage is not less than 60%.

PROTECTION HOSE: PVCcompound.

NUMBER OF CONDUCTORS:2; 3; 4; 5.

CONDUCTORAREA, mm²:0.75; 1.0; 1.5; 2.5; 4; 6.

TECHNICALSPECIFICATIONS

Operating temperature range: for КГВКбШвcable - from -40˚Сto +60˚С. For КГВКбГ cable - from +1˚Сto +40˚С.

Cable passes a 5 minutes' voltage test (without immersion in water) of 2.5 kV at 50 Hz frequency between conductors and between conductors and armor.

Maximal operation conductor heating temperature: +70°С

Cablesof all models are resistant to bending.

Minimal cabling and operating bend radius shall not be less than fifteenouter cable diameters.

Protection hose of КГВКбШвcable is sealed.

Cables do not spread combustion when single laid.

Factory cable length - not less than 50 m.

Operational life of cables - not less than 5 years.

Regulations: Technical SpecificationsBY 500017371.056-2009